Table 1: Flowline overall heat-transfer coefficient (OHTC) for various subsea insulation systems | |||||||
Flowline OHTC (W/m2°K) | |||||||
Flowline OD (mm) |
Bare Pipe | Coated Pipe 50 mm PPF k = 0.17 (W/m°K) |
Buried Pipe 1.3 m k = 1.0 (W/m°K) |
Buried & Coated | PIP 114.3 in 219.1 219.1 in 323.9 323.9 in 457.2 |
||
114.3 | 871 | 4.65 | 4.56 | 2.52 | 1.56 | ||
219.1 | 544 | 4.04 | 2.87 | 1.81 | 1.44 | ||
323.9 | 362 | 3.81 | 2.22 | 1.5 | 1.02 | ||